DVS-008W01-MC02

Product Introduction

Features & Benefits

  • Supports IEEE 802.1p based QoS for packet forwarding precedence
  • Built-in Broadcast Storm Protection
  • Transparent transmission of VLAN tagged packets
  • 12 to 48 VDC redundant terminal block power input
  • Auto warning by relay output for link-down and power failure
  • Compatible with various industrial protocols of EtherNet/IP, Profinet, CC-LINK IE and DNP 3.0
Specifications
  • Technology
    1. Standard Compliance
    2. IEEE 802.3 10Base-T
    3. IEEE 802.3u 100Base-T(X) and 100Base-FX
    4. IEEE 802.3x Flow Control
    5. IEEE 802.1p Class of Service, Priority Protocols
    6. Processing Type
    7. Store and Forward
    8. IEEE 802.3x Flow control in full duplex, back-pressure flow control in half duplex
  • Interface
    1. Fast Ethernet Ports
    2. RJ45 Ports: 6 10/100Base-T(X), auto MDI/MDI-X, auto negotiation
    3. Fiber Optic Ports: 2 100Base-FX (SC connector), MultiMode – 5km
    4. Alarm Contacts(DO)
    5. 1 relay output
    6. Carry current 5 A@24VDC
  • Performance and Scalability
    1. Switching Capacity: 1.6Gbps, Wired speed, Non-blocking switching fabric
    2. Forwarding Rate: 2.4Mpps
    3. MAC Address Table: 8K
    4. Packet Buffer Memory: 1M bits
    5. Broadcast Storm Protection: Default enabled
    6. Transparent Forwarding VLAN Tagged Packets: Default enabled
    7. IEEE 802.1p based QoS: Default enabled
  • Power Requirements
    1. Input Voltage: 2 sets, 12 to 48 VDC redundant terminal block input
    2. Input Current: Max. 0.45A
    3. Overload Current Protection: Present, Max. input current 3A
    4. Reverse Polarity Protection: Present
    5. Buffer Time: Min. 13ms at 24VDC
  • Physical
    1. Housing: IP40 aluminum metal case
    2. Dimensions: 145.3 mm(H) × 75 mm(W) × 108.7 mm (D)
    3. Weight: 430g
    4. Installation: Industrial DIN-Rail and wall mounting
  • Environmental Limits
    1. Operating Temperature: -40℃ to 75℃(-40℉ to 167℉)
    2. Storage Temperature: -40℃ to 85℃(-40℉ to 185℉)
    3. Ambient Relative Humidity: 5% to 95%(non-condensing)
  • Approvals
    1. Safety: UL 508, EN 60950-1, IEC 61131-2
    2. EMI: FCC 47 CFR Part 15 Subpart B Class B, IEC 61000-6-4, EN 55022
    3. EMS: IEC 61000-6-2
    4. Environmental Type Tests
    5. Cold Temperature: IEC 60068-2-1
    6. Dry Heat: IEC 60068-2-2
    7. Humidity: IEC 60068-2-30
    8. Shock: IEC 60255-21-2
    9. Freefall: IEC 60068-2-32
    10. Vibration: IEC 60068-2-6
    11. Hi-Pot: 1.5KV